dc.contributor.author | Pawade, Tania A | |
dc.contributor.author | Cartlidge, Timothy R G | |
dc.contributor.author | Jenkins, William S A | |
dc.contributor.author | Adamson, Philip D | |
dc.contributor.author | Robson, Phillip | |
dc.contributor.author | Lucatelli, Christophe | |
dc.contributor.author | Van Beek, Edwin J R | |
dc.contributor.author | Prendergast, Bernard | |
dc.contributor.author | Denison, Alan R | |
dc.contributor.author | Forsyth, Laura | |
dc.contributor.author | Rudd, James H F | |
dc.contributor.author | Fayad, Zahi A | |
dc.contributor.author | Fletcher, Alison | |
dc.contributor.author | Tuck, Sharon | |
dc.contributor.author | Newby, David E | |
dc.contributor.author | Dweck, Marc R | |
dc.date.accessioned | 2016-11-30T16:28:26Z | |
dc.date.available | 2016-11-30T16:28:26Z | |
dc.date.issued | 2016-10-12 | |
dc.identifier | 72468243 | |
dc.identifier | 24d85eec-a62f-4e94-bde4-d7548194fef1 | |
dc.identifier | 27733431 | |
dc.identifier | 84994164307 | |
dc.identifier.citation | Pawade , T A , Cartlidge , T R G , Jenkins , W S A , Adamson , P D , Robson , P , Lucatelli , C , Van Beek , E J R , Prendergast , B , Denison , A R , Forsyth , L , Rudd , J H F , Fayad , Z A , Fletcher , A , Tuck , S , Newby , D E & Dweck , M R 2016 , ' Optimization and Reproducibility of Aortic Valve 18F-Fluoride Positron Emission Tomography in Patients With Aortic Stenosis ' , Circulation. Cardiovascular imaging , vol. 9 , no. 10 , e005131 . https://doi.org/10.1161/CIRCIMAGING.116.005131 , https://doi.org/10.1161/CIRCIMAGING.116.005131/-/DC1 | en |
dc.identifier.issn | 1941-9651 | |
dc.identifier.other | PubMedCentral: PMC5068186 | |
dc.identifier.uri | http://hdl.handle.net/2164/7780 | |
dc.description | Sources of Funding The study was funded by the British Heart Foundation (FS/14/78/31020). Drs Pawade, Cartlidge, Jenkins, Dweck, and Newby are supported by the British Heart Foundation (SS/CH/09/002/26360, FS/13/77/30488, SS/CH/09/002/2636, FS/14/78/31020, and CH/09/002). Dr Newby is the recipient of a Wellcome Trust Senior Investigator Award (WT103782AIA). Dr Dweck is the recipient of the Sir Jules Thorn Award for Biomedical Research 2015. Dr Adamson is supported by New Zealand Overseas Training and Research Fellowship (1607) and Edinburgh and Lothians Health Foundation (50–534). The Wellcome Trust Clinical Research Facility and the Clinical Research Imaging Centre are supported by NHS Research Scotland (NRS) through NHS Lothian. Dr Rudd is partly supported by the NIHR Cambridge Biomedical Research Centre, the British Heart Foundation, and the Wellcome Trust. The Data Supplement is available at http://circimaging.ahajournals.org/lookup/suppl/doi:10.1161/CIRCIMAGING.116.005131/-/DC1. | en |
dc.format.extent | 1203098 | |
dc.language.iso | eng | |
dc.relation.ispartof | Circulation. Cardiovascular imaging | en |
dc.subject | 18F-Fluoride | en |
dc.subject | aortic valve stenosis | en |
dc.subject | calcification | en |
dc.subject | disease progression | en |
dc.subject | echocardiography | en |
dc.subject | positron emission tomography | en |
dc.subject | R Medicine | en |
dc.subject | British Heart Foundation | en |
dc.subject | FS/14/78/31020 | en |
dc.subject | SS/CH/09/002/26360 | en |
dc.subject | FS/13/77/30488 | en |
dc.subject | SS/CH/09/002/2636 | en |
dc.subject | CH/09/002 | en |
dc.subject | Wellcome Trust | en |
dc.subject | WT103782AIA | en |
dc.subject.lcc | R | en |
dc.title | Optimization and Reproducibility of Aortic Valve 18F-Fluoride Positron Emission Tomography in Patients With Aortic Stenosis | en |
dc.type | Journal article | en |
dc.contributor.institution | University of Aberdeen.Medical Education | en |
dc.contributor.institution | University of Aberdeen.Centre for Healthcare Education and Research Innovation (CHERI) | en |
dc.description.status | Peer reviewed | en |
dc.identifier.doi | 10.1161/CIRCIMAGING.116.005131 | |