Show simple item record

dc.contributor.authorPawade, Tania A
dc.contributor.authorCartlidge, Timothy R G
dc.contributor.authorJenkins, William S A
dc.contributor.authorAdamson, Philip D
dc.contributor.authorRobson, Phillip
dc.contributor.authorLucatelli, Christophe
dc.contributor.authorVan Beek, Edwin J R
dc.contributor.authorPrendergast, Bernard
dc.contributor.authorDenison, Alan R
dc.contributor.authorForsyth, Laura
dc.contributor.authorRudd, James H F
dc.contributor.authorFayad, Zahi A
dc.contributor.authorFletcher, Alison
dc.contributor.authorTuck, Sharon
dc.contributor.authorNewby, David E
dc.contributor.authorDweck, Marc R
dc.date.accessioned2016-11-30T16:28:26Z
dc.date.available2016-11-30T16:28:26Z
dc.date.issued2016-10-12
dc.identifier72468243
dc.identifier24d85eec-a62f-4e94-bde4-d7548194fef1
dc.identifier27733431
dc.identifier84994164307
dc.identifier.citationPawade , T A , Cartlidge , T R G , Jenkins , W S A , Adamson , P D , Robson , P , Lucatelli , C , Van Beek , E J R , Prendergast , B , Denison , A R , Forsyth , L , Rudd , J H F , Fayad , Z A , Fletcher , A , Tuck , S , Newby , D E & Dweck , M R 2016 , ' Optimization and Reproducibility of Aortic Valve 18F-Fluoride Positron Emission Tomography in Patients With Aortic Stenosis ' , Circulation. Cardiovascular imaging , vol. 9 , no. 10 , e005131 . https://doi.org/10.1161/CIRCIMAGING.116.005131 , https://doi.org/10.1161/CIRCIMAGING.116.005131/-/DC1en
dc.identifier.issn1941-9651
dc.identifier.otherPubMedCentral: PMC5068186
dc.identifier.urihttp://hdl.handle.net/2164/7780
dc.descriptionSources of Funding The study was funded by the British Heart Foundation (FS/14/78/31020). Drs Pawade, Cartlidge, Jenkins, Dweck, and Newby are supported by the British Heart Foundation (SS/CH/09/002/26360, FS/13/77/30488, SS/CH/09/002/2636, FS/14/78/31020, and CH/09/002). Dr Newby is the recipient of a Wellcome Trust Senior Investigator Award (WT103782AIA). Dr Dweck is the recipient of the Sir Jules Thorn Award for Biomedical Research 2015. Dr Adamson is supported by New Zealand Overseas Training and Research Fellowship (1607) and Edinburgh and Lothians Health Foundation (50–534). The Wellcome Trust Clinical Research Facility and the Clinical Research Imaging Centre are supported by NHS Research Scotland (NRS) through NHS Lothian. Dr Rudd is partly supported by the NIHR Cambridge Biomedical Research Centre, the British Heart Foundation, and the Wellcome Trust. The Data Supplement is available at http://circimaging.ahajournals.org/lookup/suppl/doi:10.1161/CIRCIMAGING.116.005131/-/DC1.en
dc.format.extent1203098
dc.language.isoeng
dc.relation.ispartofCirculation. Cardiovascular imagingen
dc.subject18F-Fluorideen
dc.subjectaortic valve stenosisen
dc.subjectcalcificationen
dc.subjectdisease progressionen
dc.subjectechocardiographyen
dc.subjectpositron emission tomographyen
dc.subjectR Medicineen
dc.subjectBritish Heart Foundationen
dc.subjectFS/14/78/31020en
dc.subjectSS/CH/09/002/26360en
dc.subjectFS/13/77/30488en
dc.subjectSS/CH/09/002/2636en
dc.subjectCH/09/002en
dc.subjectWellcome Trusten
dc.subjectWT103782AIAen
dc.subject.lccRen
dc.titleOptimization and Reproducibility of Aortic Valve 18F-Fluoride Positron Emission Tomography in Patients With Aortic Stenosisen
dc.typeJournal articleen
dc.contributor.institutionUniversity of Aberdeen.Medical Educationen
dc.contributor.institutionUniversity of Aberdeen.Centre for Healthcare Education and Research Innovation (CHERI)en
dc.description.statusPeer revieweden
dc.identifier.doi10.1161/CIRCIMAGING.116.005131


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record