University of Aberdeen

AURA - Aberdeen University Research Archive

View Item 
  •   AURA Home
  • 5 - All Research
  • All research
  • View Item
  •   AURA Home
  • 5 - All Research
  • All research
  • View Item
  •   AURA Home
  • 5 - All Research
  • All research
  • View Item
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Screening tests for detecting open angle glaucoma : systematic review and meta-analysis

      View/Open
      Mowatt G 2008.pdf (330.0Kb)
      Publication date
      09/07/2008
      Author
      Mowatt, Graham
      Burr, Jennifer Margaret
      Cook, Jonathan Alistair
      Siddiqui, M. A. Rehman
      Ramsay, Craig R
      Fraser, Cynthia Mary
      Azuara-Blanco, Augusto
      Deeks, Jonathan J
      Metadata
      Show full item record
      Abstract
      PURPOSE. To assess the comparative accuracy of potential screening tests for open angle glaucoma (OAG). METHODS. Medline, Embase, Biosis (to November 2005), Science Citation Index (to December 2005), and The Cochrane Library (Issue 4, 2005) were searched. Studies assessing candidate screening tests for detecting OAG in persons older than 40 years that reported true and false positives and negatives were included. Meta-analysis was undertaken using the hierarchical summary receiver operating characteristic model. RESULTS. Forty studies enrolling over 48,000 people reported nine tests. Most tests were reported by only a few studies. Frequency-doubling technology (FDT; C-20-1) was significantly more sensitive than ophthalmoscopy (30, 95% credible interval [CrI] 0–62) and Goldmann applanation tonometry (GAT; 45, 95% CrI 17–68), whereas threshold standard automated perimetry (SAP) and Heidelberg Retinal Tomograph (HRT II) were both more sensitive than GAT (41, 95% CrI 14–64 and 39, 95% CrI 3–64, respectively). GAT was more specific than both FDT C-20-5 (19, 95% CrI 0-53) and threshold SAP (14, 95% CrI 1-37). Judging performance by diagnostic odds ratio, FDT, oculokinetic perimetry, and HRT II are promising tests. Ophthalmoscopy, SAP, retinal photography, and GAT had relatively poor performance as single tests. These findings are based on heterogeneous data of limited quality and as such are associated with considerable uncertainty. CONCLUSIONS. No test or group of tests was clearly superior for glaucoma screening. Further research is needed to evaluate the comparative accuracy of the most promising tests.
      Citation
      Mowatt, G., Burr, J.M., Cook, J.A., Siddiqui, M.A.R., Ramsay, C, Fraser, C., Azuara-Blanco, A., and Deeks, J.J., (2008) Screening tests for detecting open angle glaucoma : systematic review and meta-analysis. Investigative Ophthalmology and Visual Science, 49, pp. 5373-85.
      URI
      http://hdl.handle.net/2164/317
      Collections
      • All research

      Browse

      All of AURACommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects
      Top of Page
      • AURA Home
      • Accessibility
      • PURE
      • Digital Resources
      • Library, Special Collections & Museums
      • Take-Down Notice
      • Send Feedback
      • Contact Us
         
       
      Library, Special Collections and Museums logo
      The Sir Duncan Rice Library
      University of Aberdeen
      Bedford Road
      Aberdeen
      AB24 3AA

      Tel: +44 (0)1224 273330
      Email: library@abdn.ac.uk
       
         

      Share and keep up to date

      FacebookTwitterWordpress

      • AURA Home
      • Accessibility
      • PURE
      • Digital Resources
      • Library, Special Collections & Museums
      • Take-Down Notice
      • Send Feedback
      • Contact Us