Show simple item record

dc.contributor.authorMoorhead, T William J
dc.contributor.authorGountouna, Viktoria-Eleni
dc.contributor.authorJob, Dominic E
dc.contributor.authorMcIntosh, Andrew M
dc.contributor.authorRomaniuk, Liana
dc.contributor.authorLymer, G Katherine S
dc.contributor.authorWhalley, Heather C
dc.contributor.authorWaiter, Gordon D
dc.contributor.authorBrennan, David
dc.contributor.authorAhearn, Trevor S
dc.contributor.authorCavanagh, Jonathan
dc.contributor.authorCondon, Barrie
dc.contributor.authorSteele, J Douglas
dc.contributor.authorWardlaw, Joanna M
dc.contributor.authorLawrie, Stephen M
dc.date.accessioned2011-02-14T13:18:47Z
dc.date.available2011-02-14T13:18:47Z
dc.date.issued2009-05-15
dc.identifier1283059
dc.identifier83aef620-fdde-4e07-a89f-5b67f0c15586
dc.identifier19445668
dc.identifier66949132962
dc.identifier.citationMoorhead , T W J , Gountouna , V-E , Job , D E , McIntosh , A M , Romaniuk , L , Lymer , G K S , Whalley , H C , Waiter , G D , Brennan , D , Ahearn , T S , Cavanagh , J , Condon , B , Steele , J D , Wardlaw , J M & Lawrie , S M 2009 , ' Prospective multi-centre Voxel Based Morphometry study employing scanner specific segmentations : procedure development using CaliBrain structural MRI data ' , BMC Medical Imaging , vol. 9 , 8 . https://doi.org/10.1186/1471-2342-9-8en
dc.identifier.issn1471-2342
dc.identifier.otherORCID: /0000-0002-5313-9845/work/64218601
dc.identifier.urihttp://hdl.handle.net/2164/1129
dc.format.extent12
dc.format.extent659959
dc.language.isoeng
dc.relation.ispartofBMC Medical Imagingen
dc.subjectadulten
dc.subjectbrainen
dc.subjectcalibrationen
dc.subjectfemaleen
dc.subjectGreat Britainen
dc.subjecthumansen
dc.subjectimage enhancementen
dc.subjectimage interpretation, computer-assisteden
dc.subjectimaging, three-dimensionalen
dc.subjectmagnetic resonance imagingen
dc.subjectmaleen
dc.subjectmiddle ageden
dc.subjectprospective studiesen
dc.subjectquality assurance, health careen
dc.subjectreference valuesen
dc.subjectreproducibility of resultsen
dc.subjectsensitivity and specificityen
dc.subjectR Medicineen
dc.subject.lccRen
dc.titleProspective multi-centre Voxel Based Morphometry study employing scanner specific segmentations : procedure development using CaliBrain structural MRI dataen
dc.typeJournal articleen
dc.contributor.institutionUniversity of Aberdeen.Applied Medicineen
dc.contributor.institutionUniversity of Aberdeen.Aberdeen Biomedical Imaging Centreen
dc.contributor.institutionUniversity of Aberdeen.Other Applied Health Sciencesen
dc.description.statusPeer revieweden
dc.identifier.doihttps://doi.org/10.1186/1471-2342-9-8
dc.identifier.vol9en


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record